Implant Overdenture Bar

3DBioCAD Truzir Screw-retain Implant Bridge

3D BioCAD Truzir Screw-retain Implant Bridge is translucent and strong. It has excellent biocompatibility and aesthetics.

Please ask us for available implant platform for Truzir Screw-retain Implant Bridge.

3DBioCAD Truzir Screw-retain Implant Bridge Features

3DBioCAD Truzir Screw-retain Implant Bridge Images Gallery

3DBioCAD Truzir Screw-retain Implant Bridge Demonstration

3DBioCAD Truzir Screw-retain Implant Bridge Additional Information

Recommended sintering schedule

R.T.~ 1000oC 100 min 10oC/min
1000oC ~ 1300oC 60 min 5oC/min
1300oC ~ 1550oC 100 min 2oC/min
1550oC 120 min holding Holding
1550oC ~ 900oC 120 min 5oC/min
900oC 30 min holding Holding
900oC ~ 700oC 20 min 10oC/min
700oC ~ R.T. 50 min 14oC/min

Faster Sintering Schedule

R.T.~ 1100oC 50 min 22oC/min
1100oC ~ 1550oC 100 min 5oC/min
1550oC 90 min holding Holding
1550oC ~ 700oC 60 min 14oC/min

3DBioCAD Truzir Screw-retain Implant Bridge Specification

Machine3DBioCAD Truzir Screw-retain Implant Bridge
Sintering temperature(oC) 1550
Bending Strength (Mpa) 1200
Sintering Density (g/m3) 6.05
Average Grain Size (um) 0.4
Amount of monoclinic phase after accelerated ageing (%) <10
Light transmittance 43% (sample thickness 1mm)
Radioactivity (Bq/g) <0.1

3DBioCAD Truzir Screw-retain Implant Bridge Part Numbers